Welcome to the PulseAid listing for the Abbott Bichromatic ABA 50 medical device. This device is used in the General Chemistry healthcare specialty. Below, you can view the analytes this device is used to test, and its corresponding complexity (HIGH, MODERATE, or CLIA WAIVED). We have also randomly listed additional medical devices used in the General Chemistry healthcare specialty at the bottom of the page.

Analytes Measured/Detected and Complexity:

ANALYTECOMPLEXITY
Alanine aminotransferase (ALT) (SGPT) (CDC000006 | CDC000006) HIGH
Effective Date: 1993-07-26
Albumin (CDC000006 | CDC000006) HIGH
Effective Date: 1993-07-26
Alkaline phosphatase (ALP) (CDC000006 | CDC000006) HIGH
Effective Date: 1993-07-26
Alpha-hydroxybutyrate dehydrogenase (HBDH) (CDC000006 | CDC000006) HIGH
Effective Date: 1993-07-26
Amylase (CDC000006 | CDC000006) HIGH
Effective Date: 1993-07-26
Aspartate aminotransferase (AST) (SGOT) (CDC000006 | CDC000006) HIGH
Effective Date: 1993-07-26
Bilirubin, direct (CDC000414 | CDC000414) HIGH
Effective Date: 1993-07-26
Bilirubin, total (CDC000414 | CDC000414) HIGH
Effective Date: 1993-07-26
Calcium, total (CDC000414 | CDC000414) HIGH
Effective Date: 1993-07-26
Carbon dioxide, total (CO2) (CDC000414 | CDC000414) HIGH
Effective Date: 1993-07-26
Chloride (CDC000414 | CDC000414) HIGH
Effective Date: 1993-07-26
Cholesterol (CDC000414 | CDC000414) HIGH
Effective Date: 1993-07-26
Creatine kinase (CK) (CDC000414 | CDC000414) HIGH
Effective Date: 1993-07-26
Creatinine (CDC000415 | CDC000415) HIGH
Effective Date: 1993-07-26
Gamma glutamyl transferase (GGT) (CDC000415 | CDC000415) HIGH
Effective Date: 1993-07-26
Glucose (CDC000415 | CDC000415) HIGH
Effective Date: 1993-07-26
Lactate dehydrogenase (LDH) (CDC000416 | CDC000416) HIGH
Effective Date: 1993-07-26
Lactate dehydrogenase heart fraction (LDH-1) (CDC000419 | CDC000419) HIGH
Effective Date: 1993-07-26
Lactate dehydrogenase liver fraction (LLDH) (CDC000417 | CDC000417) HIGH
Effective Date: 1993-07-26
Magnesium (CDC000417 | CDC000417) HIGH
Effective Date: 1993-07-26
Phosphorus (CDC000417 | CDC000417) HIGH
Effective Date: 1993-07-26
Potassium (CDC000417 | CDC000417) HIGH
Effective Date: 1993-07-26
Protein, total (CDC000417 | CDC000417) HIGH
Effective Date: 1993-07-26
Sodium (CDC000418 | CDC000418) HIGH
Effective Date: 1993-07-26
Triglyceride (CDC000418 | CDC000418) HIGH
Effective Date: 1993-07-26
Urea (BUN) (CDC000418 | CDC000418) HIGH
Effective Date: 1993-07-26
Uric acid (CDC000418 | CDC000418) HIGH
Effective Date: 1993-07-26

Other General Chemistry Devices:

Medical DeviceComplexity
Olympus AU 5131View Complexity
Bio-Chem Laboratory Systems ATAC 2000/2100View Complexity
Dade Behring BN ProSpec SystemView Complexity
Mallinckrodt Gem Premier PlusView Complexity
Beckman System 6300 Series Amino Acid AnalyzerView Complexity
Beckman Coulter Synchron LX20 PRO SystemView Complexity
Roche Diagnostics cobas e 602 AnalyzerView Complexity
INSTRUMENTATION LABORATORY ILAB 900View Complexity
Beckman Coulter Synchron CX9 ALXView Complexity
Ortho-Clinical Diagnostics VITROS 4600 Chemistry SystemView Complexity